Features
30Aswitchingcapability
• Breakdown voltage (between contact and coil): 4kV
• Creepage distance: 5.5mm
• Plastic sealed and flux proofed types available
• Product in accordance to IEC 60335-1 available
• UL insulation system: Class F
• Environmental friendly product (RoHS compliant)
• Outline Dimensions: (32.2 x 27.5x 20.4) mm
Contact arrangement | 1A | 1B | 1C |
Contact resistance | 100m max. (at 1A 6VDC) |
Contact material | AgSnO2 |
Contact rating | 30A | 15A | 20A | 10A |
(Res. load) | 277VAC | 277VAC | 277VAC | 277VAC |
Max. switching voltage | 277VAC |
Max. switching current | 30A | 30A | 30A | 15A |
Max. switching power | 8310VA | 8310A | 8310A | 4155A |
Mechanical endurance | 1 x 1 07Ops |
1) Electrical endurance | 1 x 105Ops (NO: 30A277VAC, Resistive load, Room temp., 1son 9s off) |
Notes: 1) For plastic sealed type, the venting-hole should be opened in electrical endurance test.
CHARACTERISTICS
Insulation resistance | 1000MQ (at500VDC) |
Dielectric strength | Between open contacts | 1500VAC 1min |
Between coil & contacts | 2500VAC1min(Standard) 4000VAC1min(VType) |
Surge voltage | 6kV(1.2/50|js) |
Operate time (at nomi. volt.) | 15ms max. |
Release time (at nomi. volt.) | 10ms max. |
Shock | Functional | 98m/s2 |
resistance | Destructive | 980m/s2 |
Vibration resistance | 10Hzto55Hz 1.5mm DA |
Humidity | 5% to 85% RH |
Ambient temperature | -40°Cto85°C |
Termination | PCB |
Unit weight | Approx. 25g |
Construction | Plastic sealed |
| | Flux proofed |
Notes: 1) The data shown above are initial values.
COIL
Coil power ^ Approx. 900mW
COIL DATA at23 C
Nominal Voltage VDC | Pick-up Voltage VDC max. | Drop-out Voltage VDC min. | Max. Voltage VDC1) | Coil Resistance 0 |
5 | 3.75 | 0.5 | 6.5 | 27x(1±10%) |
6 | 4.50 | 0.6 | 7.8 | 40x(1±10%) |
9 | 6.75 | 0.9 | 11.7 | 97x(1±10%) |
12 | 9.00 | 1.2 | 15.6 | 155x(1±10%) |
15 | 11.25 | 1.5 | 19.5 | 256x(1±10%) |
18 | 13.50 | 1.8 | 23.4 | 380x(1±10%) |
24 | 18.00 | 2.4 | 31.2 | 660x(1±10%) |
482) | 36.00 | 4.8 | 62.4 | 2560x(1±10%) |
702) | 52.50 | 7.0 | 91.0 | 5500x(1±10%) |
1102) | 82.50 | 11.0 | 143.0 | 13450x(1±10%) |
Notes: 1) Maximum voltage refers to the maximum voltage which relay coil could endure in a short period of time.
2) For products with rated voltage ^ 48V, measures should be taken to prevent coil overvoltage in order to protect coil in test and application (eg. Connect diodes in parallel).
SAFETYAPPROVAL RATINGS
UL/CUL | NO | 30A 277VAC at 85C 20A 277VAC at105C 2HP 240VAC/1HP 120VAC at 40C 96LRA30FLA277VAC at 40C TV-8 125VAC at 40C |
| NC | 30A 277VACat40C 20A 277VACat85C 15A 277VACat40C |
| NO | 30A 250VACat60C 20A 250VACat85C |
VDE | NC | 15A 250VACat85C |
| CO | 20A/10A 250VAC at 85C |
Notes: 1)All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications can be available upon request.
ORDERING INFORMATION
| HFi65FD | /i2 | -H | Yi | S | T | F | V | (XXX) |
Type | | | | | | | | | |
Coil voltage 5,6,9,i2,i5,i8,24,48,70,ii0
Contact arrangement H: i Form A D: i Form B Z: i Form C
Termination Y1: Without Pin NO.6 Y2: With Pin NO.6
ConstructionS: Plastic sealed Nil: Flux proofed
Contact material T: AgSnO2
Insulation standard F: Class F
D.|t. t th Nil: Standard product(2500VAC Between coil & contacts) Dtiafnd<ardC strength V : High Dielectric strength(Only for Yi Termination)
(4000VAC Between coil & contacts)
Special code2) XXX: Customer special requirement Nil: Standard
Notes: i) We recommend flux proofed types for a clean environment (free from contaminations like H2S, SO2, NO2, dust, etc.).
We suggest to choose plastic sealed types and validate it in real application for an unclean environment (with contaminations like H2S, SO2, NO2, dust, etc.).
2) The customer special requirement express as special code after evaluating by Hongfa. e.g.(335) stands for product in accordance to IEC60335-i(GWT).
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice. We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user's responsibility to determine which product should be used only.