Features
100ALatchingrelay
• Making test 1500A 10ms
short circuit current without explosion
• Heavy load up to 27700VA
• 4kV dielectric strength (between coil and contacts)
• Micro switch on mounting board available
• Environmental friendly product (RoHS compliant)
• Outline Dimensions: (60.0 x 40.0 x 21.0) mm
CONTACT DATA |
Contact arrangement | 1A, 1B |
Contact resistance | Typ.:0.35W max.(at 100A)1) |
Contact material | AgSn2 |
Contact rating (Res. load) | 100A 277VAC/28VDC |
Max. switching voltage | 440VAC |
Max. switching current | 100A |
Max. switching power | 27700VA/2800W |
Mechanical endurance | 1 x 105ops |
Electrical endurance | 1 x 104ops (100A220VAC, Resistive load, Room temp., 1s on 9s off) |
CHARACTERISTICS
Insulation resistance | 1000MQ (at500VDC) |
Dielectric | Between coil & contacts | 4000VAC 1 min |
strength | Between open contacts | 2000VAC 1 min |
Creepage distance | 8mm |
Set time (at nomi. volt.) | 20ms max. |
Reset time (at nomi. volt.) | 20ms max. |
Shock | Functional | 294m/s2 |
resistance | D estructive | 980m/s2 |
Vibration resistance | 10Hzto 55Hz 1.5mm DA |
H umidity | 5% to 85% RH |
Ambient temperature | -40oC to 70oC |
Termination | QC |
Unit weight | Approx. 100g |
Construction | Dust protected |
COIL
Coil power
Single coil latching: Approx. 2.4W Double coils latching: Approx. 4.8W
COIL DATA
at 238C
Notes: 1) Typical value: Sampling quantity for contact resistance shall not less than 20 pcs, take the average value from 5 continous measurements for each sample.
Nominal Voltage VDC | Set / Reset Voltage VDC max. | Pulse Duration ms min. | Coil Resistance x(1±10%)£3 |
6 | 4.8 | 100 | Single coil latching | 16 |
12 | 9.6 | 100 | 60 |
24 | 19.2 | 100 | 250 |
48 | 38.4 | 100 | 1000 |
6 | 4.8 | 100 | Double coils latching | 8+8 |
12 | 9.6 | 100 | 30+30 |
24 | 19.2 | 100 | 125+125 |
48 | 38.4 | 100 | 500+500 |
Notes: When requiring other nominal voltage, special order allowed.
Notes: The data shown above are initial values.
Notice:
1. Relay is on the "reset" or "set" status when being released from stock, with the consideration of shock risen from transit and relay mounting, relay would be changed to "set" or "reset" status, therefore, when application (connecting the power supply), please reset the relay to "set" or "reset" status on request.
2. In order to maintain "set" or "reset" status, energized voltage to coil should reach the rated voltage, impulse width should be 5 times more than "set" or "reset" time. Do not energize voltage to "set" coil and "reset" coil simultaneously. And also long energized time (more than 1 min) should be avoided.
3. The terminals of relay without twisted copper wire can not be tin-soldered, can not be moved willfully.
4. Relays used for metering measuring applications are usually made with dust proof structure, while most relays could be made specially per customer's specific requirements.No longer than 6 months' storage time is recommended for this kind of relay, and please pay attention to the storage environment. To ensure contact reliability, we will keep contact status be closed when delivery if no special required by customer.
Disclaimer
The specification is for reference only. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user's responsibility to determine which product should be used only.