High sensitivity: 98-mW (Rated power consumption:
200mW) pickup coil power.
• Impulse withstand voltage of 1,500V (10x160 ^s) meets
FCC requirements.
• Stick packing employed in consideration of supporting
automatic implementation.
• Plastic-sealed model that allows automatic soldering.
• New series of ultrasonically cleanable models is available.
• Standard model conforms to UL/CSA standards.
Application Examples
• Telecommunication equipment
• Office automation machines
• Industrial equipment
• Security equipment
Model Number Legend
G6E-@Δ-Δ-Δ
1 2 3 4 5 6 78
1. Relay Function
None
U
K
Single-side stable Single-winding latching Double-winding latching
2. Number of poles/ Contact Form
1: 1-pole/SPDT (1c)
3. Contact Type
3: Bifurcated crossbar Ag (Au-Alloy) contact
4. Enclosure Rating
4: Fully sealed
5. Terminals Shape
P: PCB terminals
6. Classification
None : Standard L : Low sensitivity coil (400 mW)
7. Approved Standards
US: UL, CSA UL: FILE No.E41515 \
(CSA: FILE NoR31928]
8. Special Function
None
U
Standard
For ultrasonically
cleanable
Ordering Information
•Standard Models (UL, CSA certified)
Relay Function | Single-side stable | Single-winding latching | Double-winding latching | Minimum packing unit |
Classification | Standard | Low-sensitivity | Standard | Standard | Low-sensitivity |
Contact form | Model | Rated coil voltage | Model | Rated coil voltage | Model | Rated coil voltage | Model | Rated coil voltage | Model | Rated coil voltage |
SPDT (1c) | G6E -134P-US | 5 VDC | G6E -134PL-US | 5 VDC | G6EU -134P-US | 5 VDC | G6EK -134P-US | 5 VDC | G6EK -134PL-US | 5 VDC | 25 pcs/tube |
6 VDC | 6 VDC | 6 VDC | 6 VDC | 6 VDC |
9 VDC | 9 VDC | 9 VDC | 9 VDC | - |
12 VDC | 12 VDC | 12 VDC | 12 VDC | 12 VDC |
24 VDC | 24 VDC | 24 VDC | 24 VDC | 24 VDC |
48 VDC | | | | | | | | |
•Models for Ultrasonically Cleanable
Relay Function | Single-side stable | Single-winding latching | Double-winding latching | Minimum packing unit |
Classification | Standard | Low-sensitivity | Standard | Standard |
Contact form | Model | Rated coil voltage | Model | Rated coil voltage | Model | Rated coil voltage | Model | Rated coil voltage |
SPDT (1c) | G6E -134P-US-U | 5 VDC | G6E -134PL-US-U | 5 VDC | G6EU -134P-US-U | 5 VDC | G6EK -134P-US-U | 5 VDC | 25 pcs/tube |
6 VDC | - | - | - |
9 VDC | - | - | - |
12 VDC | 12 VDC | 12 VDC | 12 VDC |
24 VDC | 24 VDC | - | 24 VDC |
48 VDC | - | - | - | - | - | - |
Note: When ordering, add the rated coil voltage to the model number.
Example: G6E-134P-US DC5
Rated coil voltage
However, the notation of the coil voltage on the produc
atings
•Coil: Single-side Stable
Classification | Rated voltage | Rated current (mA) | Coil resistance (Ω) | Must operate voltage (V) | Must release voltage (V) | Max. voltage (V) | Power consumption (mW) |
% of rated voltage |
Standard | 5 VDC | 40.0 | 125 | 70% max. | 10% min. | 190% (at 23°C) | Approx. 200 |
6 VDC | 33.3 | 180 |
9 VDC | 22.2 | 405 |
12 VDC | 16.7 | 720 |
24 VDC | 8.3 | 2,880 |
48 VDC | 8.3 | 5,760 | 170% (at 23°C) | Approx. 400 |
Low-sensitivity | 5 VDC | 79.4 | 63 | 70% max. | 10% min. | 170% (at 23°C) | Approx. 400 |
6 VDC | 66.6 | 90 |
9 VDC | 44.3 | 203 |
12 VDC | 33.3 | 360 |
24 VDC | 16.7 | 1,440 |
Coil: Single-winding latching
Contact type | Rated voltage | Rated current (mA) | Coil resistance (Ω) | Must set voltage (V) | Must reset voltage (V) | Max. voltage (V) | Power consumption |
% of rated voltage | Set coil (mW) | Reset coil (mW) |
Bifurcated crossbar | 5 VDC | 40.0 | 125 | 70% max. | 70% max. | 190% (at 23°C) | Approx. 200 | Approx. 200 |
6 VDC | 33.3 | 180 |
9 VDC | 22.2 | 405 |
12 VDC | 16.7 | 720 |
24 VDC | 8.3 | 2,880 |
•Coil: Double-winding latching
Classification | Rated voltage | Rated current (mA) | Coil resistance (Q) | Must set voltage (V) | Must reset voltage (V) | Max. voltage (V) | Power consumption |
Set coil | Reset coil | Set coil | Reset coil | % of rated voltage | Set coil (mW) | Reset coil (mW) |
Standard | 5 VDC | 40.0 | 40.0 | 125 | 125 | 70% max. | 70% max. | 190% (at 23°C) | Approx. 200 | Approx. 200 |
6 VDC | 33.3 | 33.3 | 180 | 180 |
9 VDC | 22.2 | 22.2 | 405 | 405 |
12 VDC | 16.7 | 16.7 | 720 | 720 |
24 VDC | 8.3 | 8.3 | 2,880 | 2,880 |
Low-sensitivity | 5 VDC | 79.4 | 79.4 | 63 | 63 | 70% max. | 70% max. | 170% (at 23°C) | Approx. 400 | Approx. 400 |
6 VDC | 66.6 | 66.6 | 90 | 90 |
9 VDC | 44.3 | 44.3 | 203 | 203 |
12 VDC | 33.3 | 33.3 | 360 | 360 |
24 VDC | 16.7 | 16.7 | 1,440 | 1,440 |
Note I.The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2.Operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
4. Refer to the engineering data for relations between the ambient temperature and maximum coil voltage.
Contacts
Load Item | Resistive load | Inductive load (cos =0.4; L/R = 7 ms) |
Contact type | Bifurcated crossbar |
Contact material | Ag (Au-Alloy) |
Rated load | 0.4 A at 125 VAC; 2 A at 30 VDC | 0.2 A at 125 VAC; 1 A at 30 VDC |
Rated carry current | 3 A |
Max. switching voltage | 250 VAC, 220 VDC |
Max. switching current | 3 A |
Characteristics (Including Models for Ultrasonically Cleanable)
Item Relay Function | Single-side Stable Single-winding Latching Double-winding Latching |
Contact resistance *1 | 50 mQ max. |
Operate (set) time | 5 ms max. |
Release (reset) time | 5 ms max. |
Min. set pulse width | - | 15 ms |
Min. reset pulse width | - | 15 ms |
Insulation resistance *2 | 1,000 MQ min. (at 500 VDC) |
Impulse withstand voltage | Between coil and contacts | 2,500 V (10x160 |is) (conforms to FCC part 68) |
| Between contacts of same polarity | 1,500 V (10x160 (conforms to FCC part 68) |
Dielectric strength | Between coil and contacts | 1,500 VAC, 50/60 Hz for 1 min |
| Between contacts of same polarity | 1,000 VAC, 50/60 Hz for 1 min |
Vibration resistance | Destruction | 10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude) |
| Malfunction | 10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) |
Shock resistance | Destruction | 1,000 m/s2 |
| Malfunction | 300 m/s2 |
Durability | Mechanical | 100,000,000 operations min. (at 36,000 operations/hr) |
| Electrical | 100,000 operations min. (0.4 A at 125 VAC resistive load; 0.2 A at 125 VAC inductive load) (at 1,800 operations/hr) |
| | 500,000 operations min. (2 A at 30 VDC resistive load; 1 A at 30 VDC inductive load) (at 1,800 operations/hr) |
| | 200,000 operations min. (3 A at 30 VDC resistive load) (at 1,800 operations/hr) |
Failure rate (P level) (reference value) *3 | 10 l0A at 10 mVDC |
Ambient operating temperature | -40°C to 70°C (with no icing or condenstion) |
Ambient operating humidity | 5% to 85% |
Weight | Approx. 2.7 g |
Note: The values here are initial values.
*1. The contact resistance was measured with 1 A at 5 VDC using a voltage-drop method.
*2. The insulation resistance was measured with a 500 VDC Megger Tester applied to the same parts as those used for checking the dielectric strength.
*3. This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Q.
This value may vary depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions