Features
• 31Aswitchingcapacity
• Applicable to inverter used for photovoltaic power
generation systems
• IdealforUPS
• 1.5mm contact gap (compliant to European Photovoltaic
StandardVDE0126)
1.8mm contact gap (compliant to IEC 62109-2-2011)
• The clearance distance between contact and coil is bigger
than 6.4mm, the creepage distance is bigger than 8mm.
(special code 477: 7.5mm)
• Low coil holding voltage contributes to saving energy of
equipment.
• UL insulation system: Class F
• Environmental friendly product (RoHS compliant)
• Outline Dimensions: (30.4 x 15.9 x 23.3) mm
CONTACT DATA
Contact gap | 1.5mm | 1.8mm |
Contact arrangement | 1A |
Contact resistance | 100mQ max.(at1A6VDC) |
Contact material | AgSno2 |
Contact rating | Resistive: 26A 250VAC Inductive: 31A250VAC (cos0=0.8)0.1s:10s | Resistive:26A250VAC Inductive:33A250VAC (cos0=0.8) 0.1s:10s |
Max. switching voltage | 277VAC |
Max. switching current | 31A | 33A |
Max. switching power | 7750VA | 8250VA |
Mechanical endurance | 1 x 1 06ops | 1 x 105ops |
Electrical endurance | HTtype: 3 x 104ops (26A 250VAC, Resistive load, at 75^, 1.5s on 1.5s off) |
CHARACTERISTICS
Insulation resistance | 1000MQ(at500VDC) |
Dielectric strength | Between coil & contacts | 4500VAC1min |
Between open contacts | 2500VAC1min |
Surge voltage (between coil & contacts) | 10kV(1.2/50|js) |
Operate time (at nomi. volt.) | 20ms max. |
Release time (at nomi. volt.) | 10ms max. |
Temperature rise (at nomi. volt.) | 95K max. (Contact load current 31A, rated voltage excitation, at 60C) |
70K max. (Contact load current 31A, 80% of rated voltage excitation, at 85C) |
Shock resistance | Functional | 196m/s2 |
Destructive | 980m/s2 |
Vibration resistance | 10Hzto55Hz 1.5mm DA |
Ambient temperature | -40oC to 85oC (Apply holding voltage to coil, which is 45% to 80% that of rated voltage) |
Humidity | 5% to 85% RH |
Termination | PCB |
Unit weight | Approx. 21g |
Construction | Flux proofed |
Notes: The data shown above are initial values.
COIL |
Coil power | Approx. 1.4W |
Holding voltage | 35%to120%UN(at23°C) 45%to80%UN(at85°C) |
Notes: 1)The coil holding voltage is the voltage of coil after being applied rated voltage for 100ms
2)The relay col does not allow applied more than maximum of holdingvoltagevalues for a longtime (Eg:120% Un at 23°C; 80% Un at 856C), prevent overheating burned.
COIL DATA at 23°C
Nominal Voltage VDC | Pick-up Voltage VDC max. | Drop-out Voltage VDC min. | Max. Voltage VDC* | Coil Resistance Q |
9 | 6.3 | 0.9 | 10.8 | 58x(1±10%) |
12 | 8.4 | 1.2 | 14.4 | 103x(1±10%) |
18 | 12.6 | 1.8 | 21.6 | 230x(1±10%) |
24 | 16.8 | 2.4 | 28.8 | 410x(1±10%) |
Notes: *Maximum voltage refers to the maximum voltage which relay
coil could endure in a short period of time.
SAFETY APPROVAL RATINGS
UL/CUL | AgSnO2 | 26A 277VAC at 758C 22A 277VAC at 850C |
VDE | AgSnO2 | 26A277VAC at 75 22A 277VAC at 85 |
31A250VAC cos0=0.8 0.1s:10s 33A250VAC cos0=0.8 0.1s:10s(477) |
Notes: 1)All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications can be available upon request.
ORDERING INFORMATION
| HF161F-W /12-HT(XXX) |
Type | |
Coil voltage
Contact arrangement
Contact material
Special code3)
9,12,18,24VDC H: 1 FormA
T: AgSno
XXX: Customer special requirement
Nil: Standard
Notes: 1) Water cleaning or surface process is not suggested after the flux-proofed relays are assembled on PCB.
2) Flux-proofed relays can not be used in the environment with pollutants like H2S, So2, No2, dust, etc.
3) The customer special requirement express as special code after evaluating by Hongfa. e.g. (414) stands for product with coil terminal of 1.4X0.4; e.g. (477) stands for Contact gap: 1.8mm.
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice. We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user's responsibility to determine which product should be used only.