Basic Info.
Contact Arrangement
1A, 1b, 1u, 1V
Max. Switching Voltage
440VAC
Mechanical Endurance
1 X 105OPS
Specification
52.0 x 43.0 x 22.0
Product Description
Features
• Latching relay
• 120A switching capability at Res.load
• According to the fault current and electrical life test of IEC 62055-31: UC1, UC2, UC3 (please see below table and notes2)
• 4kV dielectric strength(between coil and contacts)
• Environmental friendly product (RoHS compliant)
• Outline Dimensions: (52.0 x 43.0 x 22.0) mm
CONTACT DATA |
Contact arrangement | 1A, 1B, 1U, 1V |
Contact resistence | Typ.:0.35mQ max.(at 100A)1) |
Contact material | AgSnO2 |
Contact rating (Res. load) | 100A220VAC/28VDC |
Max. switching voltage | 440VAC |
Max. switching current | 120A |
Max. switching power | 22000VA/2800W |
Mechanical endurance | 1 x 105ops |
Notes: 1)Typical value: Sampling quantity for contact resistance shall not less than 20 pcs, take the average value from 5 continous measurements for each sample.
CHARACTERISTICS
Insulation resistance | 1000M (at500VDC) |
Dielectric | Between coil & contacts | 4000VAC 1min |
strength | Between open contacts | 2000VAC 1min |
Creepage distance | 8mm |
Set time (at nomi. volt.) | 20ms max. |
Reset time (at nomi. volt.) | 20ms max. |
Shock | Functional | 98m/s2 |
resistance | Destructive | 980m/s2 |
Vibration resistance | 10Hzto 55Hz1.5mm DA |
Humidity | 5% to 85% RH |
Ambient temperature | -40 to 85 |
Termination | QC |
Unit weight | Approx. 85g |
Construction | Dust protected |
Notes: The data shown above are initial values.
COIL
Single coil latching: Approx. 3.0W Double coils latching: Approx. 6.0W
COIL DATA at 23°C
Nominal Voltage VDC | Set / Reset Voltage VDC max. | Pulse Duration ms min. | Coil Resistance x(1±10%)Q |
6 | 4.8 | 75 | Single coil latching | 13 |
12 | 9.6 | 75 | 50 |
24 | 19.2 | 75 | 210 |
48 | 38.4 | 75 | 860 |
6 | 4.8 | 75 | Double coils latching | 6.5+6.5 |
12 | 9.6 | 75 | 25+25 |
24 | 19.2 | 75 | 105+105 |
48 | 38.4 | 75 | 430+430 |
ELECTRICAL ENDURANCE
UC Class | Voltage (Uc) | Current (Ic) | Power Factor | Close Open time (s) | Electrical endurance (ops) |
415 | | 80A | COS0=1 | | 3000 | Total:6000 |
(UC1) | | 10A | COS0=0.4 | | 3000 |
416 | | 80A | COS0=1 | | 5000 | Total:10000 |
(UC2) | 220VAC | COS0=0.5 | 10:20 | 5000 |
417 | | 100A | COS0=1 | 5000 | Total:10000 |
(UC3) | | COS0=0.5 | | 5000 |
NIL: | | 100A | COS0=1 | | 5000 | Total:10000 |
(UC3) | | | COS0=0.5 | | 5000 |
Notes: 1) Electrical endurance meet IEC62055-31 testrequirement,do
the inductive load test after the resistive load test.
2) Only some typical ratings of UC are listed above, if more special ratings required, please contact us.
Notice:
1. Relay is on the "reset" or "set" status when being released from stock, with the consideration of shock risen from transit and relay mounting, relay would be changed to "set" or "reset" status, therefore, when application (connecting the power supply), please reset the relay to "set" or "reset" status on request.
2. In order to maintain "set" or "reset" status, energized voltage to coil should reach the rated voltage, impulse width should be 5 times more than "set" or "reset" time. Do not energize voltage to "set" coil and "reset" coil simultaneously. And also long energized time (more than 1 min) should be avoided.
3. The terminals of relay without twisted copperwire can not be tin-soldered, can not be moved willfuNy.
4. relays used for metering measuring applications are usually made with dust proof structure, while most relays could be made specially per customer's specific requirements.No longer than 6 months' storage time is recommended for this kind of relay, and please pay attention to the storage environment. To ensure contact reliability, we will keep contact status be closed when delivery if no special required by customer.
Disclaimer
The specification is for reference only. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user's responsibility to determine which product should be used only.
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.
Address:
No. 777 Dushi Road. Minhang District. Shanghai. China, Shanghai, China
Business Type:
Trading Company
Business Range:
Electrical & Electronics
Company Introduction:
Our company supplies different kinds of products. High quality and reasonable price. We stick to the principle of "quality first, service first, continuous improvement and innovation to meet the customers" for the management and "zero defect, zero complaints" as the quality objective. To perfect our service, we provide the products with good quality at the reasonable price.