Features
• 7A switching capability (2C, 3C type)
• 1.5kV dielectric strength
(between coil and contacts)
• Gold plated contactavailable
• Conform to the CE low voltage directive
• Sockets available
• 2 to 4 pole configurations
• Environmental friendly product (RoHS compliant)
• Outline Dimensions: (28.0 x21.5x 35.0) mm
CONTACT DATA
Contact arrangement | 2C, 3C | 4C |
Contact resistance | 100^ max.(at 1A 6VDC) |
Contact material | See ordering info. |
Contact rating (Res. load) | 7A 250VAC/30VDC | 5A 250VAC/30VDC |
Max. switching voltage | 250VAC / 30VDC |
Max. switching current | 7A | 5A |
Max. switching power | 210W 1750VA | 150W 1250VA |
Mechanical endurance | 2 x 1 07ops |
Electrical endurance | 2Z/3Z type: 1 x 105ops (7A 250VAC, Resistive load, Room temp., 1s on9s off) 2Z/3Z type: 1 x 105ops (7A 30VDC, Resistive load, Room temp., 1s on9s off) 4Z type: 1 x 105ops (5A 250VAC, Resistive load, Room temp., 1s on9s off) 4Ztype: 1 x 105ops (5A 30VDC, Resistive load, Room temp., 1s on9s off) |
CHARACTERISTICS
Insulation resistance | 1000M (at500VDC) |
Dielectric strength | Between coil & contacts | 1500VAC1min |
Between open contacts | 1000VAC1min |
Between contact sets | 1500VAC1min |
Operate time (at nomi. volt.) | DC type: 25ms max. |
Release time (at nomi. volt.) | DC type: 25ms max. |
Temperature rise (no-load, at nomi.volt.) | 60K max. |
Shock resistance | Functional | 98m/s2 |
Destructive | 980m/s2 |
Vibration resistance | 10Hzto 55Hz1mm DA |
Humidity | 5% to 85% RH |
Ambient temperature | -40°C to70"C |
Termination | PCB, Plug-in |
Unitweight | Approx. 37g |
Construction | Dust protected |
Notes: 1) The data shown above are initial values.
COIL
Coil power DCtype:Approx.0.9Wto1.1W;
^ AC type: Approx. 1.2VA to 1.8VA
COIL DATA at 23°C
Nominal Voltage VDC | Pick-up Voltage VDC max.1) | Drop-out Voltage VDC min. | Max. Voltage vdc2) | Coil Resistance Q |
5 | 4.0 | 0.50 | 5.5 | 27.5x(1±10%) |
6 | 4.8 | 0.60 | 6.6 | 40x(1±10%) |
12 | 9.6 | 1.20 | 13.2 | 160x(1±10%) |
24 | 19.2 | 2.40 | 26.4 | 650x(1±10%) |
48 | 38.4 | 4.80 | 52.8 | 2600x(1±15%) |
110 | 88.0 | 11.0 | 121 | 11000x(1±15%) |
Nominal Voltage VAC | Pick-up Voltage VAC max.1) | Drop-out Voltage VAC min. | Max. Voltage VAC2) | Coil Resistance Q |
6 | 4.80 | 1.80 | 6.6 | 11.5x(1±10%) |
12 | 9.60 | 3.60 | 13.2 | 46x(1±10%) |
24 | 19.2 | 7.20 | 26.4 | 184x(1±10%) |
48 | 38.4 | 14.4 | 52.8 | 735x(1±10%) |
120 | 96.0 | 36.0 | 132 | 4550x(1±15%) |
220/240 | 176.0 | 72.0 | 264 | 14400x(1±15%) |
Notes: 1)Under ambient temperature, applying more than 80% of rating voltage to coil, relay will take action accordingly. But in order to meet the stated product performance, please apply rated voltage to coli.
2) Maximum voltage refers to the maximum voltage which relay coil could endure in a short period of time.
SAFETY APPROVAL RATINGS
| 2 Form C | 7A 250VAC/30VDC |
UL/CUL | 3 Form C 4 Form C | 5A 250VAC/30VDC |
TUV | 2 Form C 3 Form C | 7A 250VAC/30VDC |
4 Form C | 5A 250VAC/30VDC |
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications can be available upon request.
ORDERING INFORMATION
Remark: 1) In case of no tolerance shown in outline dimension: outline dimension <1mm, tolerance should be ±0.2mm; outline dimension >1mm and <5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
2) The tolerance without indicating for PCB layout is always ±0.1mm.