Basic Info.
Product Description
Features
Multi contactarrangements: 2NO+2NC, 3NO+1NC
• Forcibly guided contacts according to EN50205
• 6Aswitching capability
• Low input power: 360mW
• High insulation capability: 10kV surge voltage between input and output
• UL insulation system: Class F available
• Environmental friendly product (RoHS compliant)
• Outline Dimensions: (40.0 x 13.0 x 24.0) mm
CONTACT DATA | Characteristics |
Contact arrangement | 2NO+2NC (2H2D type) 3N+1NC(3H1Dtype) |
Forcibly guided contacts Type (according to EN50205) | Type A |
Contact resistance | 100m max. (at 1A6VDC) |
Contact material | AgSn2 |
Contact rating (Res. load) | 6A 250VAC / 30VDC |
Max. switching voltage | 400VAC / 30VDC |
Max. switching current | 6A |
Max. switching power | 1500VA/180W |
Electrical endurance | 1 x 1 05ops |
Mechanical endurance | 1 x105ops (1NO: 6A 30VDC, Resistiveload,at85°C,1son9soff) 5 x 104ops (1NO: 6A 250VAC, Resistiveload,at85C,1son9soff) |
COIL
Coil power
COIL DATA
at 23°C
Nominal Voltage VDC | Pick-up Voltage VDC max. | Drop-out Voltage VDC min. | Max. Voltage VDC1) | Coil resistance Cl |
6 | 4.5 | 0.6 | 7.8 | 100x(1±10%) |
9 | 6.8 | 0.9 | 11.7 | 225x(1 10%) |
12 | 9.0 | 1.2 | 15.6 | 400x(1±10%) |
18 | 13.5 | 1.8 | 23.4 | 900x(1±10%) |
24 | 18.0 | 2.4 | 31.2 | 1600x(1 10%) |
36 | 27.0 | 3.6 | 46.8 | 3600x(1±10%) |
48 2) | 36.0 | 4.8 | 62.4 | 6400x(1±10%) |
and
HONGFARELAY
Approx. 360mW
Insulation resistance | 1000M (at500VDC) |
| Between coil & contacts | 4000VAC 1 min |
Dielectric | Between open contacts | 1500VAC 1 min |
strength | Between contact sets | 2500VAC 1 min (7-8/9-10) 4000VAC 1 min (Other) |
Surge | Between coil & contacts | 10kV(1.2/50|js) |
voltage | Between contact sets | 5kV(1.2/50|js) |
Operate time (at rated voltage) | 20ms max. |
Release time (at rated voltage) | 20ms max. |
Vibration resistance | NO/NC:10Hzto55Hz 1.5mmDA NO:55Hzto200Hz,98m/s2 NC:55Hzto200Hz,49m/s2 |
Shock resistance | Functional | 100m/s2 |
Destructive | 980m/s2 |
Creepage distance | Between coil & contacts | 8mm |
Between contacts | 5.5mm |
Clearance distance | Between coil & contacts | 8mm |
Between contacts | 5.5mm |
Humidity | 5% to 85% RH |
Ambient temperature | 40oCto85oC |
Termination | PCB |
Unitweight | Approx. 20g |
Construction | Flux proofed |
Notes: 1) The data shown above are initial values. 2) UL insulation system: Class F, Class B.
SAFETY APPROVAL RATINGS
Notes: 1) Maximum voltage refers to the maximum voltage which relay
coil could endure in a short period of time.
2) For products with rated voltage ^ 48V, measures should be
taken to prevent coil overvoltage in order to protect coil in test
nd application (eg. Connect diodes in parallel).
UL/CUL | 6A 277VAC / 250VAC / 125VAC at 85oC 6A 30VDC at 85oC Pilot duty: 2A 240VAC at room temp. |
VDE | 6A 250VAC at 85oC 6A 30VDCat 85oC |
AC-15: 1.5A240VAC at room temp. AC-15: 2A 240VAC at room temp. |
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications can be available upon request.
Address:
No. 777 Dushi Road. Minhang District. Shanghai. China, Shanghai, China
Business Type:
Trading Company
Business Range:
Electrical & Electronics
Company Introduction:
Our company supplies different kinds of products. High quality and reasonable price. We stick to the principle of "quality first, service first, continuous improvement and innovation to meet the customers" for the management and "zero defect, zero complaints" as the quality objective. To perfect our service, we provide the products with good quality at the reasonable price.