Features
• Ceramic brazing sealed technology guarantees no risk of arc
leaking and ensures no fire or explosion.
• Filled with gas ( mostly hydrogen) to effectively prevent the
oxidation burnt when exposed to electricity; the contact
resistance is low and stable, and the parts exposed to electricity
can meet IP67 protection level.
• Carrying currentlOAcontinuouslyat 85° C.
• Insulation resistance is 100om)( 1000VDC), and dielectric
strength between the coil and contacts is 4KV, which meets the
requirements of IEC 60664-1.
• No specific polarity requirements for the connection
CONTACT DATA
Contact arrangement | 1H |
Contact resistence | 10m (10A) |
Rated load current | 10A |
Mechanical endurance | 2 x 105 ops |
0utline Dimensions | 66.8 x 39.0 x 48.2 mm |
| 450V type | 750V type |
Max. switching voltage | 1000V | 1000V |
Max. breaking current | 100A (450V, 1op min.) | 100A (750V, 1op min.) |
Max. switching power | 4.5kW | 7.5kW |
Electrical endurance | Res. load | Switching: 1 x 105 ops (450Vd.c., 10A) | Switching: 1 x 105 ops (750Vd.c.,10A) |
| 1000V type | |
Max. switching voltage | 1000V | |
Max. breaking current | 100A (1000V, 1op min.) | |
Max. switching power | 10kW | |
Electrical endurance1) | Res. load | Switching: 7.5 x 104ops (1000Vd.c., 10A) | |
Current carrying capacity2) | 10A: Cont. 15A: 1h 20A: 20min 40A: 30s 60A: 10s 100A: 0.6s |
Notes: 1) Until special statement, the temperature of eletrical endurance is at 23oC and the on-off ratio is 0.6s:5.4s.
2)Ambient temperature is room temperature and cross section area of wire is 2.5mm2 min. See Pic Endurance Capacity Curve for more information.
COIL
Nominal Voltage VDC | Pick-up Voltage VDC max. | Drop-out Voltage VDC min. | Coil power W |
12 | 9 | | 2.6 |
24 | 18 | 2 | 2.6 |
Notes: The values above are conservative values within the temperature rage(-40oC to 85oC), the pulling in voltage and releasing voltage are showed in the Pic Pulling in / Release Voltage Change Curve.
CHARACTERISTICS
Insulation resistance | 1000M (at1000VDC) |
Dielectric | Between coil & contacts | 4000VAC 1min. |
strength | Between open contacts | 3000VAC 1min. |
0perate time (at nomi. volt.) | 30ms max. |
Release time (at nomi. volt.) | 10ms max. |
Shock | Functional | 196m/s2 |
resistance | Destructive | 490m/s2 |
Vibration resistance | 10Hzto500Hz 49m/s2 |
Humidity | 5% to 85% RH |
Ambient temperature | -40oC to 85oC |
Termination | IS0 |
Unitweight | Approx.150g |
Notes: The data shown above are initial values.
HQNGFA RELAY
IS09001, ISO/TS16949 , IS014001,0HSAS18001, IECQ QC 080000 CERTIFIED
2016 Rev. 1.00
1
ORDERING INFORMATION
| | HFE18V | -10/ | 750- | 12- | H |
Type | V: New energy vehicle | | | | |
Contact rating | 10: 10A | | | | |
Load voltage | 750: 750VDC | Nil: 450VDC | | |
Coil voltage | 12: 12VDC | 24: 24VDC | | |
Contact arrangement H: 1 FormA | |
Load input terminal 2: QC terminal fixing
Special code1) XXX: Customer special requirement Nil: Standard
Notes: 1)The customer special requirement express as special code after evaluating by Hongfa. | |