Features
• High sensitive: 0.25W
• Lowheight:15.7 mm
• 5kV dielectric strength (between coil and contacts)
• Creepagedistance: 10mm
• Meeting VDE 0700, 0631 reinforce insulation
• Product in accordance to IEC 60335-1 available
• Socketsavailable
• Plastic sealed and flux proofed types available
• UL insulation system: Class F available
• Environmental friendly product (RoHS compliant)
• Outline Dimensions: (29.0 x 12.7 x 15.7) mm
CONTACT DATA |
Contact arrangement | 1A,1B,1C |
Contact resistance | 100mQmax.(at1A 6VDC) |
Contact material | See ordering info |
Contact rating (Sensitive coil) | 10A 250VAC |
Max. switching voltage | 440VAC / 300VDC |
Max. switching current | 10A |
Max. switching power | 2500VA |
Mechanical endurance | 1 x 107ops |
Electrical endurance | 1H3 type: 1 x 105ops (10A 250VAC Resistive load, at 85oC, 5s on 5s off) |
CHARACTERISTICS |
Insulation resistance | 1000MQ (at500VDC) |
Dielectric strength | Between coil & contacts | 5000VAC 1 min |
Between open contacts | 1000VAC 1min |
Surge voltage (between coil & contacts) | 10kV(1.2/50|js) |
Operate time (at nomi. volt.) | 15ms max |
Release time (at nomi. volt.) | 8ms max. |
Temperature rise (at nomi. volt.) | 55K max |
Shock resistance* | Functional | 98m/s2 |
Destructive | 980m/s2 |
Vibration resistance * | 10Hzto 150Hz 10g/5g |
Humidity | 5% to 85% RH |
Ambient temperature | -40 to 85 |
Termination | PCB |
Unit weight | Approx. 13.5g |
Construction | Plastic sealed, Flux proofed |
Notes: 1) The data shown above are initial values.
2 * Index is not that of relay length direction.
UL insulation system: Class F, Class B.
3) UL
HONGFA RELAY
COIL
Coil power
Approx. 250mW
COIL DATA
at 23°C
Nominal Voltage VDC | Pick-up Voltage VDC max. | Drop-out Voltage VDC min. | Max. Voltage VDC1) | Coil Resistance Q |
5 | 3.75 | 0.5 | 7.5 | 100x(1±10%) |
6 | 4.50 | 0.6 | 9.0 | 144x(1±10%) |
12 | 9.00 | 1.2 | 18 | 576x(1±10%) |
18 | 13.50 | 1.8 | 27 | 1296x(1±10%) |
24 | 18.00 | 2.4 | 36 | 2304x(1±10%) |
482) | 36.00 | 4.8 | 72 | 9216x(1±15%) |
602) | 45.00 | 6.0 | 90 | 12857 x(1 ±15%) |
Notes: 1)Maximum voltage refers to the maximum voltage which relay coil could endure in a short period of time.
2) For products with rated voltage ^ 48V, measures should be taken to prevent coil overvoltage in order to protect coil in test and application (eg. Connect diodes in parallel).
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED
SAFETYAPPROVAL RATINGS
VDE
Contact Material | Specifications | Ratings |
AgSno2 | HF115F-H....1(H;Z)(S)(1;2;3)A(G)(F) | 10A250VAC at 85°C |
AgCdO | HF115F-H....1(H;Z)(S)(1;2;3)(G)(F) | 10A250VAC at 85° C 6A400VAC at 85° C |
UL/CUL
Contact Material | Specifications | Ratings |
AgCdO | HF115F-H ….1(H;Z)(S)(1;2;3)(G)(F) | 10A 250VAC |
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications can be available upon request
ORDERING INFORMATION
HF115F-H / 012 -1HS 3S 3AF (XXX)
Type
Coil voltage 5, 6, 12, 18, 24, 48, 60VDC
Contact arrangement 1H:1 Form A 1D:1 Form B 1Z:1 Form C
Construction1)2) S: Plastic sealed Nil: Flux proofed
Version 1:3.5mm 1 pole 2: 5.0mm 1 pole 3: 5.0mm 1 pole
C t t t i 3) A:AgSno2 B:AgNi Nil: AgCdO G: AgCdO+Au plated
on ac ma eria AG: AgSno2+Au plated BG: AgNi+Au plated
Insulation standard F: Class F Nil: Class B
Special code4) XXX: Customer special requirement Nil: Standard
Notes:1) We recommend flux proofed types for a clean environment (free from contaminations like H2S, So2, No2, dust, etc.).
We suggest to choose plastic sealed types and validate it in real application for an unclean environment (with contaminations like H2S, SO2, NO2, dust, etc.).
2) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays on PCB.
3) For gold plated type, the min. switching current and min. switching voltage is 10mA 5VDC.
4) The customer special requirement express as special code after evaluating by Hongfa. e.g.(335) stands for product in accordance to IEC60335-1 (GWT)
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice. We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user's responsibility to determine which product should be used only.