Basic Info.
Rated Load
0.3 a at 125 VAC, 1 a at 30 VDC
Max. Switching Current
1 a
Release (Reset) Time
3 Ms Max.
Product Description
Subminiature model as small as 5.2 (H) x 6.5 (W) x 10 (L) mm is ideal for high-density mounting (G6K(U)-2F(-Y)).
• Low profile of 5.2 mm improves mounting efficiency (G6K(U)-2F(-Y)).
• Light weight of 0.7 g contributes to higher speed mounting.
• Surface mounting terminal models incorporate a unique terminal structure with high infrared irradiation efficiency which allows the terminal temperature to rise easily when mounting the IRS, thus ensuring excellent soldering.
• Ensures a dielectric strength of 1,500 VAC and conforms to FCC Part 68 (i.e., withstanding an impulse withstand voltage of 1,500 V for 10 x 160 ^s).
• -Y models offer an impulse withstand voltage of 2,500 V for 2 x 10 jis (conforms to Telcordia specifications) by optimizing the distance between coil and contacts.
• Standard model conforms to UL)CSA standards, certified by BSI (EN62368-1).
• Models available with a 2.54-mm terminal pitch.
Application Examples
Telecommunication equipment
• Office automation machines
• Test and measurement equipment
• Building automation equipment
• Security equipment
• Industrial equipment
• Amusement equipment
• Home appliances
Ordering Information
Surface Mounting Relay
•Surface Mounting Terminal Standard Models
G
6
K
Packing | Tube Packing | Tape Packing |
Enclosure rating | Relay Function | Contact form | Model | Rated coil voltage | Minimum packing unit | Model | Rated coil voltage | Minimum packing unit | Minimum ordering unit (tape packing) |
| | | | 3 VDC | | | 3 VDC | | |
| | | | 4.5 VDC | | | 4.5 VDC | | |
| | | G6K-2F | 5 VDC | | G6K-2F-TR | 5 VDC | | |
| | | | 12 VDC | | | 12 VDC | | |
| | | | 24 VDC | | | 24 VDC | | |
| | | | 3 VDC | | | 3 VDC | | |
| | | Highly insulated | 4.5 VDC | | Highly insulated | 4.5 VDC | | |
| | | G6K-2F-Y | 5 VDC | | G6K-2F-Y-TR | 5 VDC | | |
| | | | 12 VDC | | | 12 VDC | | |
| Single-side | | | 24 VDC | | | 24 VDC | | |
| stable | | | 3 VDC | | | 3 VDC | | |
| | | | 4.5 VDC | | | 4.5 VDC | | |
| | | G6K-2G | 5 VDC | | G6K-2G-TR | 5 VDC | | |
| | | | 12 VDC | | | 12 VDC | | |
Fully sealed | | DPDT (2c) | | 24 VDC | 50 pcs/tube | | 24 VDC | 900 pcs/reel | 1,800 pcs/2 reels |
| | 3 VDC | | 3 VDC |
| | | Highly insulated | 4.5 VDC | | Highly insulated | 4.5 VDC | | |
| | | G6K-2G-Y | 5 VDC | | G6K-2G-Y-TR | 5 VDC | | |
| | | | 12 VDC | | | 12 VDC | | |
| | | | 24 VDC | | | 24 VDC | | |
| | | | 3 VDC | | | 3 VDC | | |
| | | Highly insulated | 4.5 VDC | | Highly insulated | 4.5 VDC | | |
| | | G6KU-2F-Y | 5 VDC | | G6KU-2F-Y-TR | 5 VDC | | |
| Single winding latching | | | 12 VDC | | | 12 VDC | | |
| | | 24 VDC | | | 24 VDC | | |
| | | 3 VDC | | | 3 VDC | | |
| | Highly insulated | 4.5 VDC | | Highly insulated | 4.5 VDC | | |
| | | G6KU-2G-Y | 5 VDC | | G6KU-2G-Y-TR | 5 VDC | | |
| | | | 12 VDC | | | 12 VDC | | |
| | | | 24 VDC | | | 24 VDC | | |
•PCB Terminal Standard Models
Enclosure rating Relay Function
Single-side stable
Fully sealed
Single-winding
latching
Contact form
DPDT (2c)
Model | Rated coil voltage |
G6K-2P | 3 VDC |
4.5 VDC |
5 VDC |
12 VDC |
24 VDC |
Highly insulated G6K-2P-Y | 3 VDC |
4.5 VDC |
5 VDC |
12 VDC |
24 VDC |
Highly insulated G6KU-2P-Y | 3 VDC |
4.5 VDC |
5 VDC |
12 VDC |
24 VDC |
Minimum
packing unit
50 pcs/tube
Note 1. When ordering, add the rated coil voltage to the model number. Example: G6K-2F DC3
~^-Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as 00 VDC.
Note 2. When ordering tape packing, add -TR" to the model number.
Be sure since -TR" is not part of the relay model number, it is not marked on the relay case.
When ordering tape packing, minimum order unit is 2 reels (900 pcs X 2 = 1,800 pcs).
Note 3. Surface mounting terminal (SMT) standard models are shipped in moisture-proof package.
PCB terminal standard types do not require moisture proof packaging and therefore shipped in non-moisture-proof package.
Ratings
Coil: Single-side Stable Models
Item | Rated | Coil | Must operate | Must release | Max. voltage | Power |
| current | resistance | voltage (V) | voltage (V) | (V) | consumption |
Rated voltage | (mA) | (Q) | % of rated voltage | (mW) |
3 VDC | 33.0 | 91 | | | | |
4.5 VDC | 23.2 | 194 | | | | Approx. 100 |
5 VDC | 21.1 | 237 | 80% max. | 10% min. | 150% |
12 VDC | 9.1 | 1,315 | | | |
24 VDC | 4.6 | 5,220 | | | | |
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
Coil: Single-winding Latching Models (G6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y)
Item Rated voltage | Rated current (mA) | Coil resistance (Q) | Must operate voltage (V) | Must release voltage (V) | Max. voltage (V) | Power consumption (mW) |
% of rated voltage |
3 VDC | 33.0 | 91 | | | | |
4.5 VDC | 23.2 | 194 | | | | Approx. 100 |
5 VDC | 21.1 | 237 | 75% max. | 75% max. | 150% |
12 VDC | 9.1 | 1,315 | | | | |
24 VDC | 4.6 | 5,220 | | | | |
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
Characteristics
Contacts
Item Load | Resistive load |
Contact type | Bifurcated crossbar |
Contact material | Ag (Au-Alloy contact) |
Rated load | 0.3 A at 125 VAC, 1 A at 30 VDC |
Rated carry current | 2 A |
Max. switching voltage | 125 VAC, 60 VDC |
Max. switching current | 1 A |
G
6
K
Relay Function | Single-side stable models | Single-winding latching models |
Item | G6K-2F, G6K-2G, G6K-2P | G6K-2F-Y, G6K-2G-Y, G6K-2P-Y | G6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y |
Contact resistance *1 | 100 mQ max. |
Operating (set) time | 3 ms max. |
Release (reset) time | 3 ms max. |
Minimum set/reset signal width | - | 10 ms |
Insulation resistance *2 | 1,000 MQ min. (at 500 VDC) |
Dielectric strength | Between coil and contacts | 1,500 VAC, 50/60 Hz for 1 min |
Between contacts of different polarity | 1,000 VAC, 50/60 Hz for 1 min |
Between contacts of the same polarity | 750 VAC, 50/60 Hz for 1 min |
Impulse withstand voltage | Between coil and contacts | 1,500 V (10 x 160 ^s) | 2,500 V (2 x 10 ^s), 1,500 V (10 x 160 ^s) |
Between contacts of different polarity Between contacts of the same polarity | 1,500 V (10 x 160 |
Vibration resistance | Destruction | 10-55-10 Hz, 2.5 mm single amplitude (5 mm double amplitude) and 55 to 500 Hz, 300 m/s2 |
Malfunction | 10-55-10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) and 55 to 500 Hz, 200 m/s2 |
Shock resistance | Destruction | 1,000 m/s2 |
Malfunction | 750 m/s2 |
Durability | Mechanical | 50,000,000 operations min. (at 36,000 operations/hour) |
Electrical | 100,000 operations min. (with a rated load at 1,800 operations/hour) |
Failure rate (P level) *3 | 10 )iA at 10 mVDC |
Ambient operating temperature | -40 to 70°C (with no icing or condensation) |
Ambient operating humidity | 5% to 85% |
Weight | Approx. 0.7 g |
Note:The above values are initial values.
*1. The contact resistance was measured with 10 mA at 1 VDC with a voltage-drop method.
*2. The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength.
*3. This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Q. This value may vary depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms.