Features
4Aswitchingcapability
• High sensitive: 150mW
• 1 Form C configuration
• Plastic sealed type available
• Environmental friendly product (RoHS compliant)
• Outline Dimensions: (12.5 x 7.5 x 10.0) mm
CONTACT DATA
Contact arrangement | 1A | 1C |
Contact resistance | 100^ max. (at 10mA 30mVDC) |
Contact material | AgNi +Au plated |
Contact rating (Res. load) | 1A125VAC/2A3CVDC | 0.5A125VAC1A30VDC |
Max. switching voltage | 125VAC/60VDC |
Max. switching current | 4A | 2A |
Max. switching power | 125VA/60W | 62.5VA/30W |
Min. applicableload1) | 1mA 5V |
Mechanical endurance | 1 x 107ops |
ectricalendurance2) | 9 x 104ops (1 H:1A125VAC; 1Z:0.5A125VAC, Resistive load., Room temp., 1son9s off) |
Notes: 1) Min. applicable load is reference value. Please perform the
confirmation test with the actual load before production since reference value may change according to switching frequencies, environmental conditions and expected contact resistance and reliability.
2) Electric endurance data are collected in the NO or NC contact test.
CHARACTERISTICS
Insulation resistance | 1000MQ (at500VDC) |
Dielectric | Between coil & contacts | 1000VAC 1min |
strength | Between open contacts | 400VAC 1min |
Operate time (at nomi. volt.) | 5ms max. |
Release time (at nomi. volt.) | 5ms max. |
Temperature rise (at nomi.volt.) | 65K max. |
Vibration resistance | 10Hzto55Hz 3.3mmDA |
Shock | Functional | 98m/s2 |
resistance | Destructive | 980m/s2 |
Humidity | 5% to 85% RH |
Ambient temperature | -300C to700C |
Unitweight | Approx. 2.2g |
Termination | PCB(DIP) |
Construction | Plastic sealed |
Notes: 1)The data shown above are initial values.
2) UL insulation system: ClassA
COIL
COIL DATA at 23°C
Standard type
Nominal Voltage VDC | Pick-up Voltage VDC max. | Drop-out Voltage VDC min. | Max. Voltage VDC | Coil Resistance Q |
1.5 | 1.20 | 0.15 | 2.25 | 11.3x(1±10%) |
2.4 | 1.92 | 0.24 | 3.6 | 28.8x(1±10%) |
3 | 2.40 | 0.30 | 4.5 | 45x(1±10%) |
3.5 | 3.60 | 0.45 | 5.75 | 101.3x(1±10%) |
5 | 4.00 | 0.50 | 7.5 | 125x(1 10%) |
6 | 4.80 | 0.60 | 9.0 | 180x(1±10%) |
9 | 7.20 | 0.90 | 13.5 | 405x(1 10%) |
12 | 9.60 | 1.20 | 18.0 | 720x(1±10%) |
24 | 19.20 | 2.40 | 36.0 | 2880x(1±15%) |
Sensitive type
Nominal Voltage VDC | Pick-up Voltage VDC max. | Drop-out Voltage VDC min. | Max. Voltage VDC | Coil Resistance Q |
1.5 | 1.20 | 0.15 | 2.25 | 15x(1±10%) |
2.4 | 1.90 | 0.24 | 3.6 | 38.4x(1±10%) |
3 | 2.40 | 0.30 | 4.5 | 60x(1±10%) |
4.5 | 3.60 | 0.45 | 5.75 | 135x(1: 10%) |
5 | 4.00 | 0.50 | 7.5 | 167x(1±10%) |
6 | 4.80 | 0.60 | 9.0 | 240x(1 10%) |
9 | 7.20 | 0.90 | 13.5 | 540x(1±10%) |
12 | 9.60 | 1.20 | 18.0 | 960x(1±10%) |
24 | 19.20 | 2.40 | 36.0 | 3840x(1 15%) |
Notes: 1) When user's requirements can't be found in the above table, special order allowed.
2) In case 5V of transistor drive circuit, it is recommended to use 4.5V type relay, and 3V to use 2.4V type relay.
SAFETY APPROVAL RATINGS
UL/CUL | 1Htype: 1A30VDC 2A30VDC | 1Ztype: 1A30VDC 0.3A 60VDC |
| 1A125VAC | 0.5A125VAC |
Coil power
Sensitive:Approx. 150mW; Notes: 1)All values unspecified are at room temperature.
Standard: Approx 200mW 2) Only typicalloads are listed above. Other load specifications
:~^ : can be available upon request.
ORDERING INFORMATION
Coil voltage 1.5,2.4,3,4.5,5,6, 9,12,24VDC
Contact arrangement 1H: 1 FormA 1Z: 1 Form C
Coil power S: Sensitive type P: Standard type
Special code2) XXX: Customer special requirement Nil: Standard
Notes: 1) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays on PCB.
2) The customer special requirement express as special code after evaluating by Hongfa
Notice
1) To avoid using relays under strong magnetic field which will change the parameters of relays such as pick-up voltage and drop-out voltage.
2) The relay may be damaged because of falling or when shocking conditions exceed the requirement.
3) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays on PCB.
4) Regarding the plastic sealed relay, we should leave it cooling naturally untill below 4^C after welding, then clean it and deal with coating, remarkably the temperature ofsolvents should also be controlled below 4^C.Please avoid cleaning the relay by ultrasonic, avoid using the solvents like gasoline, Freon, and so on, which would affect the configuration of relay or influence the environment.
5) Energizing coil with rated voltage is basic for normal operation of a relay, please make sure the energized voltage to relay coil have reached the rated voltage. Regarding latching relay, in order to maintain the "set" or "reset" status, impulse width of the rated voltage applied to coil should be more than 5 times of "set" or "reset" time.
6) About preferable condition of operation, storage and transportation, please refer to "Explanation to terminology and guidetines of relay