Features
20Aswitchingcapability
• 4kV dielectric strength (between coil and contacts)
• Meeting VDE 0700, 0631 reinforce insulation
• 1 FormA, 1 Form B and 1 Form C configurations
• Socketsavailable
• Plastic sealed and flux proofed types available
• UL insulation system: Class F available
• Environmental friendly product (RoHS compliant)
• Outline Dimensions: (29.0 x 13.0 x 26.5) mm
CONTACT DATA
Contact arrangement
1A, 1B, 1C
Contact resistance
50mQ max.(at1A24VDC)
Contact material Contact rating
AgSnO2, AgCdO Resistive: 16A 240VAC/24VDC 1HP 240VAC TV-8 125VAC (NO contact
Max. switching voltage
277VAC / 30VDC
Max. switching current Max. switching power Mechanical endurance
20A
5540VA/480W 1 x 1 07ops
Electrical endurance
Notes: For plastic sealed type, the venting-hole should be excised in electrical endurance test.
CHARACTERISTICS
Insulation resistance | 1000MQ (at500VDC) |
Dielectric strength | Between coil & contacts | 4000VAC 1min |
Between open contacts | 1000VAC 1min |
Operate time (at nomi. volt.) | 15ms max. |
Release time (at nomi. volt.) | 5ms max. |
Ambient temperature | -40 to 85 |
Humidity | 5% to 85% RH |
Shock resistance | Functional | 98m/s2 |
Destructive | 980m/s2 |
Vibration resistance | 10Hzto55Hz 1.5mm DA |
Termination | PCB |
Unit weight | Approx. 18.5g |
Construction | Plastic sealed, Flux proofed |
Notes: 1) The data shown above are initial values.
2) Please find coil temperature curve in the characteristic curves below.
3) UL insulation system: Class F, Class B.
COIL
Coil power
Standard: Approx.720mW Sensitive: Approx.530mW
COIL DATA
at 23°C
Standard type
1 x105OPs(NOorNC, 16A 240VAC, Resistive load, Room temp., 1son9s off) 5 x 1 04ops (NO or NC, 16A 24VDC, Resistive load, Room temp., 1son9s off)
Nominal Voltage VDC | Pick-up Voltage VDC max. | Drop-out Voltage VDC min. | Max. Voltage VDC* | Coil Resistance Q |
5 | 3.6 | 0.5 | 5.5 | 36x(1 10%) |
6 | 4.3 | 0.6 | 6.6 | 50x(1 10%) |
9 | 6.5 | 0.9 | 9.9 | 115x(1 10%) |
12 | 8.6 | 1.2 | 13.2 | 200x(1±10%) |
18 | 13.0 | 1.8 | 19.8 | 460x(1±10%) |
24 | 17.3 | 2.4 | 26.4 | 820x(1±10%) |
48 | 34.6 | 4.8 | 52.8 | 3300x(1±10%) |
60 | 43.2 | 6.0 | 66.0 | 5100x(1±10%) |
Sensitive type
Nominal Voltage VDC | Pick-up Voltage VDC max. | Drop-out Voltage VDC min. | Max. Voltage VDC* | Coil Resistance Q |
5 | 3.60 | 0.5 | 7.0 | 47x(1 10%) |
6 | 4.30 | 0.6 | 8.4 | 68x(1±10%) |
9 | 6.50 | 0.9 | 12.6 | 160x(1 10%) |
12 | 8.60 | 1.2 | 16.8 | 275x(1±10%) |
18 | 13.0 | 1.8 | 25.2 | 620x(1±10%) |
24 | 17.3 | 2.4 | 33.6 | 1100x(1±10%) |
48 | 34.6 | 4.8 | 67.2 | 4170x(1 10%) |
60 | 43.2 | 6.0 | 84.0 | 7000x(1±10%) |
Notes: 1) When requiring pick-up voltage < 72% of nominal voltage, special order allowed.
2) Suggesting to use the sensitive type.
3) *Maximum voltage refers to the maximum voltage which relay coil could endure in a short period of time.
4) Under ambient temperature, applying more than 80% of rating voltagetocoil, relaywill take action accordingly. But in orderto meet the stated product performance, please apply rated voltage to coli.
SAFETY APPROVAL RATINGS
| Standard, Sensitive | AgSnO2 | 20A/16A/12A277VAC Resistive 1HP(8 FLA) 240VAC TV-8 125VAC 16A240VAC General Use 20A/16A/12A 24VDC 10FLA 60LRA250VAC |
UL/CUL | AgCdO | 20A/16A/12A277VAC Resistive 1HP(8 FLA) 240VAC 16A240VAC General Use 20A/16A/12A 24VDC 20A125VAC General Use |
| (136) | AgSnO2 | 20A125VAC Resistive 20A277VAC/250VAC/125VAC General Use 16A 277VAC/250VAC/125VAC Resistive 20A30VDC Resistive 1/2HP250VAC/125VAC TV-10 125VAC 10FLA 60LRA250VAC |
VDE (Coil power is 530mW) | | 1 FormA | 20A250VACat70°C 16A30VDCat70°C |
AgSnO2 | 1 Form C | 16A 250VAC at 70 C 16A 30VDCat 70C NO:20A250VAC at 70C |
Notes: 1)AII values unspecified are at room temperature.
2)Only typical loads are listed above. Other load specifications can be available upon request.
ORDERING INFORMATION
HF14FW/ 012 -H S P
Type
F
(XXX)
Coil voltage 5, 6, 9, 12, 18, 24, 48, 60VDC
Contact arrangement H: 1FormA D: 1 Form B Z: 1 Form C Construction1) S: Plastic sealed(No smoky-gray cover) Nil: Flux p^ofed
Coil power P: Standard Nil: Sensitive
Contact material T: AgSnO2 Nil: AgCdO
Insulation standard F: Class F Nil: Class B
Special code4) XXX: Customer special requirement
Nil: Standard
Notes: 1) We recommend flux proofed types for a clean environment (free from contaminations like H2S, SO2, NO2, dust, etc.).
We suggest to choose plastic sealed types and validate it in real application for an unclean environment (with contaminations
like H2S, SO2, NO2, dust, etc).
2) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays on PCB.
3) The standard type is made of black cover. If smoky-gray cover is required, please add a special suffix (611) when ordering. Please take note that smoky-gray cover is only availabe for flux proofed.
4) The customer special requirement express as special code after evaluating by Hongfa.
199
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice. We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user's responsibility to determine which product should be used only.