ΩHigh-frequency characteristics (insertion loss 3 dB or less at 8 GHz)
• Miniaturized to 11.7 x 7.9 x 7.1 mm (L x W x H).
• Rated power consumption of 100 mW with high sensitivity
Model Number Legend
G6K-2F-RF-V ?2 I 4
1. Number of poles/
Contact Form
2: 2-pole/ DPDT (2c)
Application Examples)
• Semiconductor test equipment
• Test&measurement equipment
• Communication equipment
3. Special Function 1
RF: High-frequency compatible
Standard type specifications
4. Special Function 2
V: 8-GHz band
High-speed differential transmission compatible type
Note. We have a lineup of G6K (U)-2F(P)-RF(-S,-T) products for 1-GHz/3-GHz band high-frequency signal applications.
2. Terminal Shape F: Outside-L surface mounting terminals
Contact type: Bifurcated crossbar
Ag (Surface Au alloy)
Ordering Information
Relay Function | Enclosure rating | Contact form | Model | Rated coil voltage | Minimum packing unit |
Single-side stable | Fully sealed | DPDT (2c) | G6K-2F-RF-V | 4.5, 5, 12 VDC | 40 pcs/tube |
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G6K-2F-RF-V DC5
~-Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as VDC.
Ratings
•Contacts
•High-frequency Characteristics *1
Item Load | Resistive load |
Rated load | 125 VAC, 0.3 A 30 VDC, 1 A 10 VDC, 10 mA 8 GHz, 1 W * |
Rated carry current | 1 A |
Max. switching voltage | 125 VAC or 60 VDC |
Max. switching current | 1A |
* This value is for a V.SWR of 1.2 max. at the load.
Item Frequency | 8GHz |
Differential transmission characteristics | Insertion loss | 3 dB max. |
Isolation | 15 dB min. |
Return loss (V.SWR) | 5 dB min. (3.57 max.) |
Single-ended characteristics (reference value) | Insertion loss | 4 dB max. |
Isolation | Between contacts of the same polarity | 15 dB min. |
Between contacts of different polarity | 15 dB min. |
Return loss (V.SWR) | 5 dB min. (3.57 max.) |
Maximum carry power | 1 W * 2 |
Maximum switching power | 1 W * 2 |
Note 1. The impedance of the measurement system is 50 ^. (Differential impedance is 100 ^.)
Note 2.The above values are initial values.
*1. Contact your OMRON representative if the Relay will be used in an application that requires high repeatability in high-frequency characteristics.
*2. These values are for a V.SWR of 1.2 max. at the load.
Coil: Single
Item Rated voltage | Rated current (mA) | Coil resistance | Must operate voltage (V) | Must release voltage (V) | Maximum voltage (V) | Power consumption (mW) |
% of rated voltage |
4.5 VDC | 23.2 | 194 | | | | |
5 VDC | 21.1 | 237 | 80% max. | 10% min. | 150% | Approx. 100 |
12 VDC | 9.1 | 1,315 | | | | |
Note I.The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously.
Characteristics
Contact resistance *1 | 100 mQ. max. |
Operating time *2 | 3 ms max. (approx. 1.4 ms) |
Release time *2 | 3 ms max. (approx. 0.7 ms) |
Insulation resistance *3 | 500 MQ min. (at 500 VDC) |
Dielectric strength | Between coil and contacts | 350 VAC, 50/60 Hz for 1 min |
Between contacts of different polarity | 350 VAC, 50/60 Hz for 1 min |
Between contacts of the same polarity | 350 VAC, 50/60 Hz for 1 min |
Between ground and coil/contacts | 350 VAC, 50/60 Hz for 1 min |
Vibration resistance | Destruction | 10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude) |
Malfunction | 10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) |
Shock resistance | Destruction | 1,000 m/s2 |
Malfunction | 750 m/s2 |
Durability | Mechanical | 50,000,000 operations min. (at a switching frequency of 36,000 operations/hour) |
Electrical | 1,000,000 operations min. (10 VDC, 10 mA, at a switching frequency of 1,800 operations/hour) |
100,000 operations min. (Other rated load, at a switching frequency of 1,800 operations/hour) |
Ambient operating temperature | -40°C to 70°C (with no icing or condensation) |
Ambient operating humidity | 5% to 85% |
Weight | Approx. 1.16 g |
Note. The above values are initial values.
*1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
*2. Values in parentheses are actual values.
*3. The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength.