Features
70Aswitching capability
• Extendedtemp.rangeupto125°C
• With transientsuppression resistoravailable
• 1 Form A contact arrangement
• Plastic sealed and dust protected types available
• RoHS & ELV compliant
Typical Applications
Fog lamp&headlight control, Rearwindowdefogger,Air-conditioning, Powerdistribution, Fuel pump control, ABS, Traction control system, Cooling fan control, Heating control, Power supply managementsystem, Battery disconnection device
CHARACTERISTICS
Contact arrangement | 1A |
Voltage drop (initial) | Typ.: 30mV (at10A) Max.:250mV (at10A) |
Max. continuous current1J 10) | 70A(at23eC); 50A(at85C) |
Max. switching current10) | 70A |
Max. switching voltage 2) | 50VDC |
Min. contact load | 1A 6VDC |
Electrical endurance | See "CONTACT DATA" |
Mechanical endurance | 1 x 107ops (300OPS/min) |
Initial insulation resistance | 100M (at500VDC) |
Dielectric strength 3) | 500VAC |
Operate time 10) | Typ.: 6ms (atnomi.vol.) Max.:10ms (atnomi.vol.) |
Release time 4) 10) | Typ.: 4ms Max.: 7ms |
Ambient temperature | -40 to 125' |
Vibration resistance 5) 10) | 10Hzto55Hz 3.0mm DA 55Hzto500Hz 100m/s2 |
Shock resistance5"0) | 294m/s2 |
Flammability 6) | UL94-HB or better (meets FMVSS 302) |
Termination | QC, PCB 7) |
Construction | Plastic sealed, Dust protected |
Unit weight | Approx. 38g |
Mechanical data 8) | cover retention (pull & push): 200N min. terminal retention (pull & push): 100N min. terminal resistance to bending (front &side): 10N min. 9) |
1) For 70Atype, measured when applying 100% rated votage on coil.
2) For 70Atype, see "Load limit curv " for details.
3) 1min, leakage current less than 1mA
4) The value is measured when voltage drops suddenly from nominal voltage to 0 VDC and coil is not paralleled with suppression circuit.
5) When energized, opening time of NO contacts shall not exceed 100^s.
6) FMVSS 302: Federal MotorVehicle Safety Standard.
7) Since it is an environmental friendly product, please select lead-free solder when welding. The recommended soldering temperature and timeis(250±3) ,(5±0.3)s.
8) Only valid for QC version.
9) Test point is at 2mm away from teminal end, and after removing testing force, the terminal transfiguration shall not exceed 0.5mm.
10) Only for the 12VDC coil voltage type.
CONTACT DATA4) |
Load voltage | Load type | Load current A | On/Off ratio | Electrical endurance OPS | Contact material | Load wiring diagram 3) | Ambient temp. |
Osn | Off s |
Standard 13.5VDC | Resistive | Make | 70 | 2 | 2 | 1x105 | AgSnO2 | See diagram 1 | at 23OC |
Break | 70 |
Inductive | Make 1) | 150 | 2 | 4 | 1x105 | AgSnO2 | See diagram 2 | See Ambient temp. curve |
Break | 50 |
Lamp 2) | Make | 200 | 0.5 | 10 | 1x105 | AgSnO2 | See diagram 3 |
Break | 40 |
Standard 27VDC | Resistive | Make | 40 | 2 | 2 | 1x105 | AgSnO2 | See diagram 1 | at 23°C |
Break | |
COIL DATA at23 C |
| Nominal voltage VDC | Pick-up voltage VDC max. | Drop-out voltage VDC min. | Coil resistance x(1±10%)Q | Parallel resistance x(1 5%)C | Equivalent resistance Q | Power consumption W | Max. allowable overdrive voltage 1JVDC |
| | | | | | | | at 23 | at 85 |
Standard | 6 | 3.6 | 0.6 | 22.5 | --- | --- | 1.6 | 10 | 9 |
| 6 | 3.6 | 0.6 | 22.5 | 180 | 20 | 1.8 | 9 | 9 |
| 12 | 7.2 | 1.2 | 90 | --- | --- | 1.6 | 21 | 18 |
| 12 | 7.2 | 1.2 | 90 | 680 | 79.5 | 1.8 | 18 | 18 |
| 24 | 14.4 | 2.4 | 360 | --- | --- | 1.6 | 43 | 34 |
| 24 | 14.4 | 2.4 | 360 | 2700 | 317.6 | 1.8 | 36 | 34 |
High power consumption | 6 | 3.6 | 0.6 | 18 | --- | --- | 2.0 | 9 | 7 |
| 6 | 3.6 | 0.6 | 18 | 180 | 16.4 | 2.2 | 9 | 7 |
| 12 | 7.2 | 1.2 | 72 | --- | --- | 2.0 | 19 | 14 |
| 12 | 7.2 | 1.2 | 72 | 680 | 65.1 | 2.2 | 18 | 14 |
| 24 | 14.4 | 2.4 | 288 | --- | --- | 2.0 | 39 | 28 |
| 24 | 14.4 | 2.4 | 288 | 2700 | 260.2 | 2.2 | 36 | 28 |
ORDERING INFORMATION
| HFV7 / | 012- | H | 4 | S | P | T | M | -R |
Type HFVde | | | | | | | | |
Coilvoltage 006:6VDC 012:12VDC 024:24VDC
Contact arrangement H: 1 FormA
4: Plastic Bracket 6: Metal Bracket
Nil: No Bracket
Version
Construction ~
S: Plastic sealed 2) Nil: Dust protected
Coil power Contact material
P: High power consumption T: AgSnO2
Nil: Standard
Length of terminal
M: Shortterminal& QCtype 14.5mm
Nil: Long terminal & QC type 17mm, or PCB type
R: Parallel transient supression resistors
Parallel coil D: Parallel transient supression diode, with anode connected to terminal#85 components D1: Parallel transient supression diode, with anode connected to terminal#86 Nil: Withoutparallelcomponents
Load type (L): Low load type 40A(Only for 12VDC and QC type) Nil: Standard type 70A
Special code4)
XXX: Customer special requirement
Nil: Standard
Notes: 1) Dust protected version is recommended.
2) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays on PCB.
3) If parallel diode, Zener Diode or other components are required, please contact Hongfa for more technical supports.
4) The customer special requirement express as special code after evaluating by Hongfa. e.g. (170) stands for flasher load
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.
In case there is specific criterion (such as mission profile, technical specification, PPAP etc.) checked and agreed by and between customer and Hongfa, this specific criterion should be taken as standard regarding any requirement on Hongfa product.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to choose the suitable productfortheir own application. Ifthere is any query, please contact Hongfa forthe technical service. However, it isthe user's responsibility to determine which product should be used only.