Features
5Aswitchingcapability
• 3kV dielectric strength (between coil and contacts)
• Slim size (width 5mm, height 12.5mm)
• Highsensitive: Min.120mW
• Meets IEC61131-2 reinforce insulation
• Creepage/clearance distance: Min. 3.5mm
• Sockets available
• UL insulation system: Class F available
• Environmental friendly product (RoHS compliant)
• Outline Dimensions: (20.0 x 5.0 x 12.5) mm
CONTACT DATA
Contact arrangement | 1A |
Contact Resistance (at 1A 6VDC) | No gold plated: 100mQ max. Gold plated: 50^ max. |
Contact material | AgSnO2, AgNi |
Contact rating (Res. load) | 5A 250VAC/30VDC |
Max. switching voltage | 250VAC/30VDC |
Max. switching current | 5A |
Max. switching power | 1250VA/150W |
Min. contact load 1) | No gold plated: 5VDC 10mA Gold plated: 5VDC 1mA |
Mechanical endurance | 2 x 1 07ops |
Electrical endurance | 1 x 105ops (3A250VAC/30VDC, Resistive load, AgNi, at 85oC, 1son9s off) 5 x 1 04ops (5A 250VAC/30VDC, Resistive load, AgNi, Room temp., 1 s on 9s off) |
Notes:1) Min. contact load is reference value. Please perform the confirmation testwith the actual load before usage since reference value may change according to switching frequencies, environmental conditions and expected life cycles.
CHARACTERISTICS
Insulation resistance | 1000M (at500VDC) |
Dielectric strength | Between coil & contacts | 3000VAC 1min |
Between open contacts | 1000VAC 1min |
Surge voltage(between coil & contacts) | 6kV(1.2/50|js) |
Operate time (at nomi.volt.) | 10ms max. |
Release time (at nomi.volt.) | 5ms max. |
Shock resistance | Functional | 98m/s2 |
Destructive | 980m/s2 |
Vibration resistance | 10Hzto 55Hz1.5mm DA |
Humidity | 5% to 85% RH |
Ambient temperature | -40°C to85C |
Termination | PCB |
Unit weight | Approx. 3g |
Construction | Plastic sealed |
Notes: 1) The data shown above are initial values.
2) Please find coil temperature curve in the characteristic curves below.
3) UL insulation system: Class F, Class B, ClassA.
COIL
Approx. 120mW (at 5VDC to 18VDC) Approx. 180mW (at 24VDC)
COIL DATA at 23°C |
Nominal Voltage VDC | Pick-up Voltage VDC max. | Drop-out Voltage VDC min. | Max. Voltage VDC* | Coil Resistance Q |
5 | 3.50 | 0.25 | 6.0 | 208x(1±10%) |
6 | 4.20 | 0.30 | 7.2 | 300x(1±10%) |
9 | 6.30 | 0.45 | 10.8 | 675x(1±10%) |
12 | 8.40 | 0.60 | 14.4 | 1200x(1 10%) |
18 | 12.6 | 0.90 | 21.6 | 2700x(1±15%) |
24 | 16.8 | 1.20 | 28.8 | 3200x(1±15%) |
Notes: 1)All above data are tested when the relaysterminals are downward position. Other positions of the terminals, the pick-up and drop- outvoltageswillhave±5%tolerance.Forexample,whentherelay terminals are transverse position, the max. pick-up voltage change is 75% of nominal voltage.
2) *Maximum voltage refers to the maximum voltage which relay coil could endure in a short period of time.
3) 24VDC 120mW type are also available, please see ordering information for more details.
SAFETY APPROVAL RATINGS
UL/CUL | 1H1 type | AgSn2 | 3A250VACCOS0=1at85oC 3A30VDC L/R=0msat85oC 5A250VAC COS0=1 5A30VDC L/R=0ms |
AgNi |
1H2 type | AgNi | 3A250VAC COS0=1at85oC 3A30VDC L/R=0msat85oC 5A250VAC COS0=1 5A30VDC L/R=0ms |
VDE | 5A250VAC COS0=1at85oC 5A30VDC L/R=0msat85oC |
TUV | 5A 250VAC COS0=1 at 70oC 5A30VDC L/R=0msat70oC |
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications can be available upon request.