Features
• Extendedtemp.rangeupto125°C
• 1 FormA& 1 Form C contact arrangement
• 2.8mm QC terminals
• RoHS & ELV compliant
CHARACTERISTICS
Contact arrangement | 1A, 1C |
Voltage drop (initial) | NO:Typ.20mV,250mV max.(at10A) NC:Typ.25mV,250mV max.(at10A) |
Max.continuous current" | 35A(at125°C,1h) |
Max.switching current | Make(NO): 150A2) Break(NO): 35A(Resistive, 13.5VDC) |
Max. switching voltage | See "Load limit curve" |
Min. contact load | 1A 6VDC |
Electrical endurance | See "CONTACT DATA" |
Mechanical endurance | 1x107ops 300OPS/min |
Initial insulation resistance | 100MQ(at500VDC) |
Dielectric strength 3) | between contacts: 500VAC between coil & contacts: 500VAC |
Operate time | Typ.: 5ms (at nomi. vol.) Max.: 10ms (at nomi. vol.) |
Release time4) | Typ.: 3ms Max.: 10ms |
Ambient temperature | -40 to 125' |
Vibration resistance 5) | 10Hzto40Hz 1.27mm DA 40Hzto 70Hz 49m/s2 70Hzto 100Hz 0.5mm DA 100Hzto500Hz 98m/s2 |
Shock resistance 5) | 196m/s2 |
Flammability 6) | UL94-HB or better (meets FMVSS 302) |
Termination | 2.8mm QC |
Construction | Plastic sealed, Dust protected |
Unitweight | Approx. 20g |
Mechanical data | cover retention (pull & push): 200N min. terminal retention (pull & push): 100N min. terminal resistance to bending (front & side): 10N min. 7) |
1) For NO contacts, measured when applying 100% rated votage on coil.
2) Inrush peak current under lamp load, at 13.5VDC.
3) 1min, leakage current less than 1mA.
4) The value is measured when voltage drops suddenly from nominal voltage to 0 VDC and coil is not paralleled with suppression circuit.
5) When energized, opening time of NO contacts shall not exceed 1ms, when non-energized, opening time of NC contacts shall not exceed 1ms, meantime, NO contacts shall not be closed.
6) FMVSS: Federal Motor Vehicle SafetyStandard.
7) Test point is at 2mm away from teminal end, and after removing testing force, the terminal transfiguration shall not exceed 0.5mm.
CONTACT DATA2) |
Load voltage | Load type | Load current A | On/Off ratio | Electrical endurance OPS | Contact material | Load wiring diagram1) | Ambient temp. |
1C | 1A | On s | Off s |
NO | NC | NO |
13.5VDC | Resistive | Make | 35 | 20 | 35 | 2 | 2 | 1x105 | AgSnO2 | See diagram 1 | See Ambient Temp. Curve |
Break | 35 | 20 | 35 |
Lamp | Make | 150 | --- | 150 | 2 | 2 | 1x105 | AgSnO2 | See diagram 2 |
Break | 30 | --- | 30 |
Inductive | Make | 80 | --- | 80 | 2 | 2 | 1x105 | AgSnO2 | See diagram 3 |
Break | 33 | --- | 33 |
HONGFA RELAY
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED
2015 Rev. 1.00
108
1) The load wiring diagrams are listed below (Ratings of NO, NC are tested based on different samples seperately):
30 c 87
R Resistive
diagram 1
Lamp diagram 2
Inductive diagram 3
2) Loads mentioned in this chart is for relays with no parallel diode or Zener Diode. For those with parallel diode, Zener Diode or other components, please contact Hongfa for more technical supports.
Please also contact Hongfa if the actual application load is diffrent from what mentioned aboved.
COIL DATA
at 23°C
Nominal voltage VDC | Pick-up voltage VDC max. | Drop-out voltage VDC min. | Coil resistance x(l 10%)Q | Parallel resistance x(1 5%)Q | Equivalent resistance Q | Power consumption W | Max. allowable overdrive voltage 1J VDC |
at 23 | at 85 |
12 | 7.2 | 1.2 | 124 | --- | --- | 1.2 | 20.4 | 14.9 |
12 | 7.2 | 1.2 | 124 | 680 | 104.9 | 1.4 | 20.4 | 14.9 |
1) Max. allowable overdrive voltage is stated with no load applied.