32.2 x 27.4 x 19.4mm
Product Description
Features • 35Aswithingcapitable. • Applicable to inverter used for photovoltaic power generation systems. • IdealforUPS. • 1.8mm contact gap(compliant to European Photovoltaic Standard VDE0126). • Product in accordance to IEC 60335 available. • Low coil hoilding voltage contributes to saving energy of equipment. • ULinsulationsystem: class F. • Environmental friendly product (RoHS compliant). • Outline Dimensions: (32.2 x 27.4 x 19.4) mm. |
Contact arrangement | 1A |
Voltage drop | Typ.: 15mV(at 10A) Max.: 100mV(at 10A) |
Contact material | AgSn2 |
Contact rating | Resistive: 35A250VAC |
(Res. load) | Inductive: 35A277VAC (cos0=0.8) 1s:9s |
Max. switching voltage | 277VAC |
1) Max. switching current | 35A |
Max. switching power | 9695VA |
Mechanical endurance | 1 x 106 ops |
Electrical endurance | 3x104ops (35A 250VAC, Resistive load, at 85oC, 1son9s off) |
Notes: 1)The relay connections and wiring have to be designed with an adequate cross setions to ensure the current flow and heat dissipation. |
Insulation resistance | 1000MQ (at500VDC) |
Dielectric | Between coil & contacts | 4000VAC1min |
strength | Between open contacts | 2500VAC 1min |
Surge voltage (between coil & contacts) | 6kV(1.2/50|js) |
Operate time (at nomi. volt.) | 15ms max. |
Release time (at nomi. volt.) | 10ms max. |
Temperature rise (at nomi. volt.) | 70K max.(Contact load current 35A, 50% of rated voltage excitation, at 85C) |
Shock resistance | Functional | 98m/s2 |
| 980m/s2 |
Vibration resistance | 10Hzto55Hz 1.5mm DA |
Ambient temperature | -40oC to 85oC (Apply holding voltage to coil) |
Humidity | 5% to 85% RH |
Termination | PCB |
Unit weight | Approx.36g |
Construction | Flux proofed |
Notes: The data shown above are initial values. |
Coil power Approx.2.25W Holdingvoltage 40%to 110%UN(at23C) ___________________ ^_______________ 50%to70%UN(at85°C) Notes: 1)The coil holding voltage is the voltage applied to coil 100ms after the rated voltage. 2)To avoid overheating and burning, the coil can not be consistently applied to with voltage larger than maximum holding voltage. |
Nominal Voltage VDC1) | Pick-up Voltage VDC max. | Drop-out Voltage VDC min. | Max. Voltage VDC* | Coil Resistance Q |
5 | 3.75 | 0.35 | 5.5 | 11.1x(1±10%) |
12 | 9 | 0.84 | 13.2 | 64x(1±10%) |
24 | 18 | 1.68 | 26.4 | 256x(1±10%) |
48 | 36 | 3.36 | 52.8 | 1024x(1±10%) |
Notes: *Maximun voltage refers to the maximun voltage which relay coil could endure in a short period of time. |
35A277VAC/250VAC general use 3x104ops at 85C 35A250VAC |
Notes: 1) All values unspecified are at room temperature. 2) Only typical loads are listed above. Other load specifications can be available upon request. |
Address:
No. 777 Dushi Road. Minhang District. Shanghai. China, Shanghai, China
Business Type:
Trading Company
Business Range:
Electrical & Electronics
Company Introduction:
Our company supplies different kinds of products. High quality and reasonable price. We stick to the principle of "quality first, service first, continuous improvement and innovation to meet the customers" for the management and "zero defect, zero complaints" as the quality objective. To perfect our service, we provide the products with good quality at the reasonable price.