Features
• 1pole16A,2pole8A,1C0 & 2 CO contacts
• 5kV dielectric, Creepage distance 8 mm (coil to contacts)
• Meeting VDE 0700, 0631 reinforce insulation
• DC/AC coil type relay , Coil power 400mW / 0.75VA
• Manual test device
• Type with mechanical indicator / electrical indicator
• Sockets available
• Environmental friendly product (RoHS compliant)
• Outline Dimensions: (29.0 x 13.0 x 25.5) mm
CONTACT DATA
COIL
Contact arrangement | 1C | 2C |
Contact resistance | 100mQ max.(at1A6VDC) |
Contact material | AgNi |
Contact rating (Res. load) | 16A 250VAC | 8A 250VAC |
Max. switching voltage | 440VAC |
Max. switching current | 16A | 8A |
Max. switching power | 4000VA | 2000VA |
Mechanical endurance | DC type: 5 x 106ops AC type: 1 x 106ops |
Electrical endurance | 1Z3B type: 3x 104ops (NO: 16A 250VAC, Resistive load, at 70oC, 1son9s off) 2Z4B type: 5 x 104ops (NO: 8A 250VAC, Resistive load, at 70oC, 1son9s off) |
CHARACTERISTICS
Insulation resistance | 1000MQ(at500VDC) |
Dielectric strength | Between coil & contacts | 5000VAC 1min |
Between open contacts | 1000VAC1min |
Between contact sets | 2500VAC1min |
Operate time (at nomi. volt.) | DC type: 15ms max. |
Release time (at nomi. volt.) | DC type: 8ms max. |
Temperature rise (at nomi. volt.) | DC type: 60K max. AC type: 85K max. |
Shock resistance* | Functiona | 98m/s2 |
Destructive | 980m/s2 |
Vibration resistance* | NO | 10Hzto 150Hz 10g |
NC | length direction: 10Hz to 150Hz 2g otherdirection: 10Hzto 150Hz5g |
Humidity | 5% to 85% RH |
Ambient temperature | -40°C to70°C |
Termination | pcb |
Unit weight | Approx. 16g |
Mounting distance | 5mm, packing of sockets |
Notes: 1) The data shown above are initial values.
2) * Index is not that of relay length direction.
3) UL insulation system: Class A
DC type: Approx. 400mW;
Notes: The data shown above don't include the power of electronic indicating circuit when the relay picks-up.
COIL DATA at 23C
DC type
Nominal Voltage VDC | Pick-up Voltage VDC max. | Drop-out Voltage VDC min. | Max. Voltage VDC1) | Coil Resistance Q |
12 | 8.4 | 1.2 | 18 | 360x(1±10%) |
24 | 16.8 | 2.4 | 36 | 1440x(1±10%) |
482) | 33.6 | 4.8 | 72 | 5760x(1±15%) |
1102) | 77.0 | 11.0 | 165 | 25200x(1±15%) |
Notes: 1) Maximum voltage refers to the maximum voltage which relay coil could endure in a short period of time.
2) For products with rated voltage ^ 48V, measures should be taken to prevent coil overvoltage in order to protect coil in test and application (eg. Connect diodes in parallel).
AC type(50Hz)
Nominal Voltage VAC | Pick-up Voltage VAC max. | Drop-out Voltage VAC min. | Coil Current mA | Coil DC Resistance Q |
24 | 18.0 | 3.6 | 31.6 | 350x(1±10%) |
115 | 86.3 | 17.25 | 6.6 | 8100x(1±15%) |
230 | 172.5 | 34.5 | 3.2 | 32500x(1±15%) |
SAFETY APPROVAL RATINGS
UL/CUL | 1 Form C | 16A 250VAC at 70' |
2 Form C | 8A 250VAC at 70 |
|
VDE | 1 Form C | 16A 250VAC at 700C |
2 Form C | 8A 250VAC at 70°C |
|
| | |
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications can be available upon request
ORDERING INFORMATION
HF115FP /024-1Z3B(XXX)
Type
Coil voltage012 to 110: 12,24,48, 110 VDC A24 to A230: 24, 115, 230 VAC
Contact arrangement 1Z: 1 Form C2Z: 2 Form C
Version3: 5.0mm 1 pole 16A 4: 5.0mm 2 pole 8A
Contact materialB: AgNi
Special code2)Customer special requirementNil: Standard
Notes: 1) Flux-proofed relays can not be used in the environment with pollutants like H2S, So2, No2, dust, etc. 2) The customer special requirement express as special code after evaluating by Hongfa.