Features
. 10Aswitchingcapability
• 5kV dielectric strength (between coil and contacts)
• Socketsavailable
• 1 Form A ,1 Form B and 1 Form C configurations
• Plastic sealed and flux proofed types available
• Environmental friendly product (RoHS compliant)
• Outline Dimensions: (29.0 x 12.6 x 20.6) mm
CONTACT DATA
COIL
Contact arrangement | 1A, 1B, 1C | Coil power | Standard: Approx. 720mW; Sensitive: Approx. 550mW |
Contact resistance | 50mQ max.(at1A 6VDC) |
Contact material | | |
A | vgSnO2,AgCdO | COIL DATA at 23°C |
Contact rating (Res.load) | Standard 8A250VAC/30VDC 10A125VAC | High Capacity 10A 30VDC 10A 250VAC | Standard type |
Nominal Voltage VDC | Pick-up Voltage VDC max. | Drop-out Voltage VDC min. | Max. Voltage VDC* | Coil Resistance Q |
Max. switching power | 2000VA/240W 2500VA/300W |
Max. switching current | 10A |
Max. switching voltage | 250VAC / 30VDC 5 | 4.0 | 0.5 | 6.5 | 36x(1 10%) |
Mechanical endurance | 1 x 1 07ops 6 | 4.8 | 0.6 | 7.8 | 50x(1 10%) |
Electrical endurance | Standard type: 1 x 105ops ( NO or NC, 8A 250VAC/30VDC, Resistiveload, Room temp., 1son9s off), High capactiy type: 1 x105OPs(NOorNC, 10A 250VAC/30VDC, Resistiveload, Room temp., 1son9s off), | 9 | 7.2 | 0.9 | 11.7 | 115x(1±10%) |
12 | 9.6 | 1.2 | 15.6 | 200x(1±10%) |
18 | 14.4 | 1.8 | 23.4 | 460x(1±10%) |
Notes: For plastic sealed type, the venting-hole should be excised in electrical endurance test. | 24 | 19.2 | 2.4 | 31.2 | 820x(1±10%) |
48 | 38.4 | 4.8 | 62.4 | 3300x(1±10%) |
CHARACTERISTICS |
Insulation resistance | 1000MQ(at500VDC) |
Dielectric strength | Between coil & contacts | 5000VAC1min |
Between open contacts | 1000VAC1min |
Operate time (at nomi. volt.) | 15ms max. |
Release time (at nomi. volt.) | 5ms max. |
Vibration resistance | 10Hzto55Hz 1.5mm DA |
Shock resistance | Functional | 98m/s2 |
Destructive | 980m/s2 |
Humidity | 5% to 85% RH |
Ambient temperature | -40C to70C |
Termination | PCB |
Unitweight | Approx. 13g |
Construction | Plastic sealed, Flux proofed |
Notes: 1) The data shown above are initial values.
2) Please find coil temperature curve in the characteristic curves below.
3) UL insulation system: ClassA
Sensitive type
Nominal Voltage VDC | Pick-up Voltage VDC max. | Drop-out Voltage VDC min. | Max. Voltage VDC* | Coil Resistance Cl |
5 | 4.0 | 0.5 | 6.5 | 47x(1±10%) |
6 | 4.8 | 0.6 | 7.8 | 68x(1±10%) |
9 | 7.2 | 0.9 | 11.7 | 155x(1±10%) |
12 | 9.6 | 1.2 | 15.6 | 270x(1±10%) |
18 | 14.4 | 1.8 | 23.4 | 620x(1±10%) |
24 | 19.2 | 2.4 | 31.2 | 1100x(1±10%) |
48 | 38.4 | 4.8 | 62.4 | 4400x(1±10%) |
Notes: 1)When requiring pick-up voltage < 80% of nominal voltage, special order allowed.
2) *Maximum voltage refers to the maximum voltage which relay coil could endure in a short period of time.
3) Under ambient temperature, applying more than 80% of rating voltage to coil, relay will take action accordingly. But in order to meet the stated product performance, please apply rated voltage to coli
SAFETY APPROVAL RATINGS |
UL/CUL | High Capacity | 10A 30VDC/250VAC |
Standard | 8A 30VDC/250VAC 10A 125VAC |
Notes: 1)AII values unspecified are at room temperature.
2)Only typical loads are listed above. Other load specifications can be available upon request
ORDERING INFORMATION
| HF141FF/ | 012 | -H | S | P |
Type | | | | | |
Coil voltage | 5, 6, 9, 12, 18, 24, 48VDC | | | |
Contact arrangement H:1 FormA D:1 Form B Z:1 | Form C | | |
Construction 1} | S: Plastic sealed | Nil: Flux proofed | |
Coil power | P: Standard Nil: Sensitive | |
Contact capacity G: High capacity (AgSno2) Nil: Standard type (AgCdO)
Special code3) XXX: Customer special requirement Nil: Standard
Notes: 1) Under the ambience with dangerous gas like H2S, SO2 or NO2, plastic sealed type is recommended; Please test the relay in real applications. If the ambience allows, flux proofed type is preferentially recommended.
2) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays on PCB.
3) The customer special requirement express as special code after evaluating by Hongfa.