Features
• Small and for microwave oven
• 20Aswitchingcapability
• 1.5HP 250VAC approved by UL standard
• 5kV impulse withstand voltage
(between coil and contacts)
• PCB & QC layouts
• Flux proofed types available
• Environmental friendly product (RoHS
CONTACT DATA
Contact arrangement | 1A |
Contact resistance | 100mQ max.(at1A6VDC) |
Contact material | AgSnO2 |
Contact rating | Resistive: 20A250VAC 1.5HP250VAC |
Max. switching voltage | 250VAC/30VDC |
Max. switching current | 20A |
Max. switching power | 5000VA/480W |
Mechanical endurance | 2 x 106ops |
Electrical endurance | 1x105ops (20A 250VAC, Resistive load, Room temp., 1son9s off) |
CHARACTERISTICS
Insulation resistance | 1000M (at500VDC) |
Dielectric strength | Between coil & contacts | 5000VAC 1min |
Between open contacts | 1000VAC 1min |
Operate time (at nomi. volt.) | 15ms max. |
Release time (at nomi. volt.) | 5ms max. |
Humidity | 5% to 85% RH |
Shock resistance | Functional | 98m/s2 |
Destructive | 980m/s2 |
Ambient temperature | -40eC to85C |
Vibration resistance | 10Hzto55Hz 1.5mm DA |
Termination | PCB & QC |
Unit weight | Approx. 16.5g |
Construction | Flux proofed |
Notes: 1)The data shown above are initial values.
2) Please find coil temperature curve in the characteristic curves below.
3) UL insulation system: Class A
COIL
Coil power Approx. 500mW
COIL DATA at23 C
Nominal Voltage VDC | Pick-up Voltage VDC max. | Drop-out Voltage VDC min. | Max. Voltage VDC* | Coil Resistance Q |
5 | 3.75 | 0.25 | 6.50 | 50x(1±10%) |
6 | 4.50 | 0.30 | 7.80 | 72x(1±10%) |
9 | 6.75 | 0.45 | 11.7 | 162x(1±10%) |
12 | 9.00 | 0.60 | 15.6 | 288x(1±10%) |
18 | 13.5 | 0.90 | 23.4 | 648x(1±10%) |
24 | 18.0 | 1.20 | 31.2 | 1152x(1±10%) |
Notes:1)When requiring pick-upvoltage <75% ofnominal voltage, special order allowed.
2) *Maximum voltage refers to the maximum voltage which relay coil could endure in a short period of time.
SAFETY APPROVAL RATINGS |
UL/CUL | 20A250VAC 16A30VDC 1.5HP250VAC |
VDE | 20A250VAC 16A30VDC |
TUV | 20A250VAC 16A30VDC |
Notes: 1)All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications can be available upon request.
ORDERING INFORMATION
| HF25F / | 012 | -H |
Type | | | |
Coil voltage | 5,6,9,12,18,24VDC | |
Contact arrangement H: 1 FormA | |
Version 1: 1 type 2: 2 type 3: 3 type 4: 4 type Nil: Standard type
Special code2) XXX: Customer special requirement Nil: Standard
Notes: 1) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays on PCB.
2) The customer special requirement express as special code after evaluating by Hongfa.